2.5" Solid State Drives

Refurbished 2.5" SSD drives for servers and storage

These are enterprise solid state drives in the 2.5in small form factor used by the hot-plug SFF bays of most rack servers and storage shelves. Many carry the Dell, HPE, Lenovo or IBM part numbers your system expects. For 12Gb RAID arrays, busy databases and multipath storage, choose from our 2.5" SAS SSDs. For boot mirrors, entry servers and controllers that only speak SATA, SATA 2.5" solid state drives are the economical fit.

Items 1-12 of 335

Buying Guide & FAQs

The 2.5in SSD has largely replaced the 10k and 15k spinning disk in server drive bays. A solid state drive stores data on NAND flash with no moving parts, so random reads and writes are orders of magnitude faster than any mechanical disk. Seek time stops being the bottleneck for virtual machines and databases.

Everything in this category connects over SAS or SATA. That means it drops into the same backplanes, carriers and RAID controllers as the 2.5 drives it replaces, with no new hardware needed. If your server has U.2 bays or spare PCI Express slots and you want NVMe, which talks to the CPU directly over PCIe lanes, look at our NVMe solid state drives. For boot adapters and onboard slots, check whether the slot is keyed for M.2 SATA or M.2 NVMe, then see our M.2 SSD range. The full refurbished server SSD catalogue brings every form factor together.

At a glance

Form factor2.5in small form factor (SFF), for hot-plug SFF bays in rack servers, towers and storage enclosures. OEM hot-plug bays need the matching vendor carrier, so check each listing for what is supplied.
Interfaces12Gb SAS (SAS3) and 6Gb SATA (SATA III). The two share a physical shape, but the SAS connector is keyed so a SATA drive will seat in a SAS bay and not the other way round.
Endurance classesRead Intensive drives suit workloads written once and read often. Mixed Use drives are rated for heavier sustained writes.
CapacitiesFrom 250GB and 400GB drives sized for boot mirrors, through 1.6TB Mixed Use models, to 3.84TB and 15.36TB Read Intensive drives for capacity tiers.
Drive familiesSamsung PM1633, PM1635a and PM1643a. HGST and Western Digital Ultrastar SSD1600MR and DC SS200. Intel DC S3610. Toshiba THNSF8 series. Micron S630DC.
Part numbersListings show the OEM number alongside the drive model. Examples include Dell codes such as V51HG, W5PP5, 65WJJ and DMF5Y, HPE spares numbers such as 844283-001, 844761-001 and P20835-001, and Lenovo and IBM numbers such as 00NA688 and 01NN772.

Typical deployments

Boot and hypervisor mirrors

An OS or hypervisor volume needs very little capacity and very little write endurance. What it needs is two identical drives in RAID 1, so a failure is a swap rather than a rebuild from scratch. Small Read Intensive SAS drives such as the Ultrastar SSD1600MR 250GB (00NA688) or the Samsung PM1633 400GB (844283-001) are ample. They also free the remaining bays for data.

Virtualisation datastores

Most VM estates read far more than they write, so Read Intensive drives give the best capacity per pound. Prioritise capacity per bay: a 3.84TB drive such as the Samsung PM1643a 3.84TB (P20835-001) lets a 2U host carry a useful datastore without an external array. Persistent VDI desktops and build servers are the exception. They write constantly and are better served by Mixed Use.

SQL and transactional databases

Here endurance matters more than headline capacity. Transaction logs, tempdb and index rebuilds wear flash quickly, so choose Mixed Use drives such as the Samsung PM1635a 1.6TB (W5PP5). Keep logs on their own mirrored pair. SAS is the better choice for this tier because the interface supports dual-port drives and deeper command queues.

Capacity consolidation

A single Dell PM1643a 15.36TB (V51HG) holds what used to take a shelf of spinning disks. This suits file servers, backup landing zones and archive tiers that still need fast reads. The trade-off is rebuild exposure. With drives this large, RAID 6 or RAID 10 is a safer layout than RAID 5, and a cold spare on the shelf is cheap insurance.

ZFS, Ceph and software-defined storage

Put the controller in HBA or IT mode so the storage layer sees each disk directly. Cache, SLOG and journal devices take a pounding, so use Mixed Use drives there. The Micron S630DC 3.84TB Mixed Use (01NN772) pairs capacity with endurance for all-flash pools. Buy matched models across nodes so performance stays predictable when data rebalances.

Entry servers, labs and SATA controllers

Onboard SATA and entry RAID controllers cannot run SAS drives, and a lab rarely justifies the cost. The Intel SSD DC S3610 series is a well-proven Mixed Use SATA design. The Intel DC S3610 400GB (65WJJ) makes a durable boot or small database drive. For more space at SATA prices, the Toshiba THNSF81D60CSE 1.6TB (DMF5Y) offers Mixed Use endurance.

Why buy from Compuwyze

  • 12-month return-to-base warranty on drives and other simple items
  • Orders for simple items placed before 2pm aim to ship the same day
  • Free UK delivery on orders over £50, normally arriving the next working day once shipped
  • International delivery via FedEx economy or priority, usually 2 to 5 days
  • 30-day returns, with return shipping paid by the customer
  • Bulk drive orders shipped boxed or on pallets through Royal Mail, FedEx, FDC or DHL

Frequently asked questions

What does SSD stand for, and is an SSD a type of RAM?

SSD stands for solid state drive. It is storage, not memory. Like a hard drive, it keeps data when the power is off, whereas RAM is volatile working memory that is cleared at shutdown. An SSD uses NAND flash chips and a controller in place of spinning platters. A server sees a 2.5in SAS or SATA SSD exactly as it would see a hard drive on the same port.

Is an SSD better than a hard drive in a server?

For anything latency-sensitive, yes. Random I/O is dramatically faster, there are no heads to crash, and an all-flash array stays responsive under mixed workloads. The disadvantages are cost per terabyte, which is still higher than large mechanical disks, and finite write endurance. That is why bulk cold storage and long-term backup often stay on spinning disks while VMs and databases move to flash.

Will a SATA SSD work on a SAS controller?

Generally yes. SAS controllers and backplanes accept SATA drives, and the link runs at SATA speed. The reverse does not apply: a SAS SSD will not work on a SATA-only controller or onboard SATA port, and its connector is keyed to prevent it. Avoid mixing SAS and SATA drives in the same RAID volume.

Do I need Read Intensive or Mixed Use?

Read Intensive drives carry a lower drive-writes-per-day rating. They suit boot volumes, VM datastores, web content and analytics, where data is written once and read many times. Mixed Use drives are built for heavier sustained writes, usually through more spare flash, and belong under databases, logging and cache tiers. If you are unsure, measure the daily write volume on your current storage and compare it with the drive's rating.

Will a Dell, HPE or Lenovo branded drive work in my server?

OEM drives usually carry that vendor's firmware and part number. Some management tools flag a drive without the expected firmware as non-certified or third party, which can affect status LEDs and alerting even when the drive works normally. The safest route is to match the part number on the listing to your server's parts list. If you are unsure, send us the server model and RAID controller before you order.

How can I check the wear on a refurbished SSD?

Every enterprise SSD reports its own health. Once the drive is installed, use smartctl on Linux, your RAID controller's utility or the server's management controller. These show a percentage-used or remaining-endurance figure, along with reallocated block counts. For production arrays, install matched drives together and keep a spare, so one worn drive never forces a rushed purchase.